Skip to content

Density Test Report

Date :03/04/2022
Project No :2021C078
Client Company :CCG Constructors LLC (Century)
Arrival Time :03/04/2022
Onsite Hours :
Name of the Project :Pickens Landing Development
Project Location :Dacula, GA
Weather :75 sunny
Departure Time :03/04/2022
ASEC Technician Name :Russell Hendrix

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
03/04/2022 1 23.7 114.4 P-5 102.4 17.8 90.3 95 D6938 Fail
Location : Sta 1+50 (Lot #1), Elv/Depth :962
Comment : Wet soils require removal, disking and aeration prior to replacment and recompaction Gauge Serial No. :38069
03/04/2022 2 26.2 109.9 P-5 102.4 17.8 85.1 95 D6938 Fail
Location : Sta 1+75, Elv/Depth :962
Comment : Wet soils require removal, disking and aeration prior to replacment and recompaction Gauge Serial No. :38069
03/04/2022 3 29.1 98.5 P-5 102.4 17.8 74.5 95 D6938 Fail
Location : Sta 1+50, Elv/Depth :963
Comment : Wet soils require removal, disking and aeration prior to replacment and recompaction Gauge Serial No. :38069
03/04/2022 4 23.5 119.8 P-5 102.4 17.8 94.7 95 D6938 Fail
Location : Sta 1+75, Elv/Depth :963
Comment : A discussion with Brad in regards to smaller lifts and more compacting. Wet soils require removal, disking and aeration prior to replacment and recompaction Gauge Serial No. :38069
Technician Signature / DateRussell Hendrix, March 4, 2022
Reviewer Name / DateRamchandra Mogulla, December 12, 2022