Skip to content

Density Test Report

Date :04/11/2022
Project No :2022C135
Client Company :Mark Spain
Arrival Time :04/02/2022
Onsite Hours :
Name of the Project : Barnett Shoals Road Development
Project Location :Watkinsville
Weather :50 sunny
Departure Time :04/02/2022
ASEC Technician Name :Russell Hendrix

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/02/2022 1 24.8 99.0 P-2 99.5 22.1 99.5 98 D6938 Pass
Location : dam keyway (2nd lift), Elv/Depth :
Comment : Gauge Serial No. :38069
04/02/2022 2 28.6 93.6 P-1 97.3 23.7 96.2 98 D6938 Fail
Location : dam keyway (3rd lift), Elv/Depth :
Comment : recompacted 3rd lift Gauge Serial No. :38069
04/02/2022 3 29.8 97.8 P-2 99.5 22.1 98.3 98 D6938 Pass
Location : dam keyway (4th lift), Elv/Depth :
Comment : 4th lift Gauge Serial No. :38069
04/02/2022 4 31.3 92.8 P-1 97.3 23.7 95.4 98 D6938 Fail
Location : dam keyway (3rd lift), Elv/Depth :
Comment : recompacted 3rd lift Gauge Serial No. :38069
04/02/2022 5 29 95.3 P-1 97.3 23.7 97.9 98 D6938 Fail
Location : dam keyway (5th lift), Elv/Depth :
Comment : (retest) 5th lift Gauge Serial No. :38069
04/02/2022 6 27.3 96.6 P-1 97.3 23.7 99.3 98 D6938 Pass
Location : dam keyway (6th lift), Elv/Depth :
Comment : Gauge Serial No. :38069
04/02/2022 7 29.3 94.4 P-1 97.3 23.7 97.0 98 D6938 Fail
Location : dam keyway (7th lift), Elv/Depth :
Comment : Gauge Serial No. :38069
04/02/2022 8 31.1 94.6 P-1 97.3 23.7 97.2 98 D6938 Fail
Location : dam keyway (8th lift), Elv/Depth :
Comment : Gauge Serial No. :38069
04/02/2022 9 33.3 92.3 P-1 97.3 23.7 94.9 98 D6938 Fail
Location : dam keyway (9th lift), Elv/Depth :
Comment : Test failed. Will recheck after recompaction Gauge Serial No. :38069
Technician Signature / DateRussell Hendrix, April 11, 2022
Reviewer Name / DateKenneth Mosman, April 24, 2022