- Home
- Density Test Report Report ID: 53543
- This project is inactive from admin.Download Report
Density Test Report
Date :04/11/2022
Project No :2022C135
Client Company :Mark Spain
Arrival Time :04/02/2022
Onsite Hours :
Name of the Project : Barnett Shoals Road Development
Project Location :Watkinsville
Weather :50 sunny
Departure Time :04/02/2022
ASEC Technician Name :Russell Hendrix
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
04/02/2022 | 1 | 24.8 | 99.0 | P-2 | 99.5 | 22.1 | 99.5 | 98 | D6938 | Pass |
Location : | dam keyway (2nd lift), Elv/Depth : | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
04/02/2022 | 2 | 28.6 | 93.6 | P-1 | 97.3 | 23.7 | 96.2 | 98 | D6938 | Fail |
Location : | dam keyway (3rd lift), Elv/Depth : | |||||||||
Comment : | recompacted 3rd lift | Gauge Serial No. :38069 | ||||||||
04/02/2022 | 3 | 29.8 | 97.8 | P-2 | 99.5 | 22.1 | 98.3 | 98 | D6938 | Pass |
Location : | dam keyway (4th lift), Elv/Depth : | |||||||||
Comment : | 4th lift | Gauge Serial No. :38069 | ||||||||
04/02/2022 | 4 | 31.3 | 92.8 | P-1 | 97.3 | 23.7 | 95.4 | 98 | D6938 | Fail |
Location : | dam keyway (3rd lift), Elv/Depth : | |||||||||
Comment : | recompacted 3rd lift | Gauge Serial No. :38069 | ||||||||
04/02/2022 | 5 | 29 | 95.3 | P-1 | 97.3 | 23.7 | 97.9 | 98 | D6938 | Fail |
Location : | dam keyway (5th lift), Elv/Depth : | |||||||||
Comment : | (retest) 5th lift | Gauge Serial No. :38069 | ||||||||
04/02/2022 | 6 | 27.3 | 96.6 | P-1 | 97.3 | 23.7 | 99.3 | 98 | D6938 | Pass |
Location : | dam keyway (6th lift), Elv/Depth : | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
04/02/2022 | 7 | 29.3 | 94.4 | P-1 | 97.3 | 23.7 | 97.0 | 98 | D6938 | Fail |
Location : | dam keyway (7th lift), Elv/Depth : | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
04/02/2022 | 8 | 31.1 | 94.6 | P-1 | 97.3 | 23.7 | 97.2 | 98 | D6938 | Fail |
Location : | dam keyway (8th lift), Elv/Depth : | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
04/02/2022 | 9 | 33.3 | 92.3 | P-1 | 97.3 | 23.7 | 94.9 | 98 | D6938 | Fail |
Location : | dam keyway (9th lift), Elv/Depth : | |||||||||
Comment : | Test failed. Will recheck after recompaction | Gauge Serial No. :38069 |
Technician Signature / DateRussell Hendrix, April 11, 2022
Reviewer Name / DateKenneth Mosman, April 24, 2022