Skip to content

Density Test Report

Date :04/11/2022
Project No :2022C135
Client Company :Mark Spain
Arrival Time :04/04/2022
Onsite Hours :
Name of the Project : Barnett Shoals Road Development
Project Location :Watkinsville
Weather :50 sunny
Departure Time :04/04/2022
ASEC Technician Name :Russell Hendrix

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/04/2022 1 26.2 99.4 P-2 99.5 22.1 99.9 98 D6938 Pass
Location : Lift #8, first section of keyway dam, Elv/Depth :
Comment : Restest from April 2nd. Gauge Serial No. :38069
04/04/2022 2 26.9 91.6 P-1 97.3 23.7 94.1 98 D6938 Fail
Location : Lift #2, new section dam keyway, Elv/Depth :
Comment : failed Gauge Serial No. :38069
04/04/2022 3 27.9 96.8 P-1 97.3 23.7 99.5 98 D6938 Pass
Location : Lift #2, new section dam keyway, Elv/Depth :
Comment : Retest of test #2 this date Gauge Serial No. :
Technician Signature / DateRussell Hendrix, April 11, 2022
Reviewer Name / DateKenneth Mosman, April 24, 2022