Skip to content

Density Test Report

Date :04/11/2022
Project No :2022C135
Client Company :Mark Spain
Arrival Time :04/05/2022
Onsite Hours :
Name of the Project : Barnett Shoals Road Development
Project Location :Watkinsville
Weather :60 cloudy
Departure Time :04/05/2022
ASEC Technician Name :Russell Hendrix

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/05/2022 1 28.1 100.3 P-1 97.3 23.7 103.1 98 D6938 Pass
Location : Dam Keyway, Elv/Depth :
Comment : Gauge Serial No. :38069
04/05/2022 2 26.5 99.5 P-2 99.5 22.1 100.0 98 D6938 Pass
Location : Dam Keyway next lift (#2), Elv/Depth :
Comment : Gauge Serial No. :38069
04/05/2022 3 26.2 97.6 P-2 99.5 22.1 98.1 98 D6938 Pass
Location : Dam Keyway lift #3, Elv/Depth :
Comment : Gauge Serial No. :38069
Technician Signature / DateRussell Hendrix, April 11, 2022
Reviewer Name / DateKenneth Mosman, April 24, 2022