Skip to content

Density Test Report

Date :05/23/2022
Project No :2022C135
Client Company :Mark Spain
Arrival Time :05/11/2022
Onsite Hours :
Name of the Project : Barnett Shoals Road Development
Project Location :Watkinsville
Weather :sunny
Departure Time :05/11/2022
ASEC Technician Name :Russell Hendrix

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
05/11/2022 1 29.9 84.4 P-1 97.3 23.7 86.7 90 D6938 Fail
Location : north side of dam, Elv/Depth :unknown
Comment : Recompaction requested and completed Gauge Serial No. :38069
05/11/2022 2 30.1 91.2 P-1 97.3 23.7 93.7 90 D6938 Pass
Location : north side of dam, Elv/Depth :unknown
Comment : Requested area be scarified prior to recompaction Gauge Serial No. :38069
05/11/2022 3 30 96.2 P-1 97.3 23.7 98.9 90 D6938 Pass
Location : Southside of dam, Elv/Depth :unknown
Comment : Requested area be scarified prior to recompaction Gauge Serial No. :38069
05/11/2022 4 30.5 95.1 P-1 97.3 23.7 97.7 90 D6938 Pass
Location : Southside Dam, Elv/Depth :unknown
Comment : Requested area be scarified prior to recompaction Gauge Serial No. :38069
Technician Signature / DateRussell Hendrix, May 23, 2022
Reviewer Name / DateKenneth Mosman, June 05, 2022