Skip to content

Density Test Report

Date :08/03/2022
Project No :2021C002
Client Company :CW Matthews
Arrival Time :08/03/2022 06:30
Onsite Hours :
Name of the Project :Runway 9L End Around Taxiway
Project Location :HJAIA
Weather :
Departure Time :
ASEC Technician Name :Nick Smith

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
08/03/2022 1 12.3 113.5 14 119.8 14.0 94.7 90 D6938 Pass
Location : Between H1 and H2, Elv/Depth :999.8
Comment : Gauge Serial No. :29588
08/03/2022 2 12.3 119.2 14 119.8 14.0 99.5 90 D6938 Pass
Location : Between H2 and H3, Elv/Depth :999.8
Comment : Gauge Serial No. :29588
08/03/2022 3 11.6 113.6 14 119.8 14.0 94.8 90 D6938 Pass
Location : At H3, Elv/Depth :999.8
Comment : Gauge Serial No. :29588
08/03/2022 4 13.2 116.0 14 119.8 14.0 96.8 95 D6938 Pass
Location : Taxiway south shoulder STA 440, Elv/Depth :
Comment : Gauge Serial No. :29588
08/03/2022 5 13.4 114.9 14 119.8 14.0 95.9 95 D6938 Pass
Location : Taxiway south shoulder STA 440+50, Elv/Depth :
Comment : Gauge Serial No. :29588
08/03/2022 6 13.1 119.8 14 119.8 14.0 100.0 95 D6938 Pass
Location : Taxiway STA 440, Elv/Depth :
Comment : Gauge Serial No. :29588
08/03/2022 7 12.1 115.0 14 119.8 14.0 96.0 90 D6938 Pass
Location : Between M2-M3, Elv/Depth :1001.5
Comment : Gauge Serial No. :29588
Technician Signature / DateNick Smith, August 3, 2022
Reviewer Name / DateKenneth Mosman, October 23, 2022