Skip to content

Daily Field Report

Date :09/19/2022
Project No :2022C205
Client Company :Pulte
Arrival Time :09/19/2022 11:00
Onsite Hours :03:00
Name of the Project :Enclave at Parkway Village
Project Location :Union City
Weather :Clear and sunny
Departure Time :09/19/2022 14:00
ASEC Technician Name :Jared Barrios

Observations/Finding

Our ASEC representative arrived on site at 11:00 am. Our ASEC representative visually inspected and conducted DCP tests on three lots: Lot #93, Lot #94 and Lot #96. Foundations on all 3 stated lots were found to meet job specifications for a soil bearing pressure of 2000 psf. Visually, the soils on all 3 lots were found to be red silty sands.

The DCP test results for Lot #93 Location A were 6, 5, 8 and AR (auger refusal) for the top 4 feet.

The DCP test results for Lot #93 Location C were 9, 13, 9 and AR (auger refusal for the top 4 feet.

The DCP test results for Lot #94 Location A were 21, 21, 13 and 11 for the top 4 feet.

The DCP test results for Lot #94 Location C were 9, 12, 9 and 12 for the top 4 feet.

The DCP test results for Lot #96 Location A were 5, 12, 10 and 11 for the top 4 feet.

The DCP test results for Lot #96 Location C were 12, 12, 12 and 13 for the top 4 feet.

Our ASEC representative departed the site at 2:00 pm following completion.

Technician Signature / DateJared Barrios, September 19, 2022
Reviewer Name / DateKenneth Mosman, October 23, 2022