Density Test Report

Date :09/30/2022
Project No :2022C135
Client Company :Mark Spain
Arrival Time :09/30/2022 10:00
Onsite Hours :06:00
Name of the Project : Barnett Shoals Road Development
Project Location :Watkinsville
Weather :Sunny
Departure Time :09/30/2022 16:00
ASEC Technician Name :Vidal Dias

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
09/30/2022 1 24.7 123.8 P-1 97.3 23.7 127.2 95 D6938 Pass
Location : Center of dam, Elv/Depth :-19 feet from top of dam
Comment : Gauge Serial No. :
09/30/2022 2 22.5 118.1 P-1 97.3 23.7 121.4 95 D6938 Pass
Location : Center of dam, Elv/Depth :-18.5 feet from top of dam
Comment : Gauge Serial No. :
09/30/2022 3 22.2 98.6 P-1 97.3 23.7 101.3 95 D6938 Pass
Location : Center of dam, Elv/Depth :17 feet from top of dam
Comment : Gauge Serial No. :
Technician Signature / DateVidal Dias, September 30, 2022
Reviewer Name / DateKenneth Mosman, October 23, 2022