Date :10/28/2022
Project No :2022C135
Client Company :Mark Spain
Arrival Time :10/28/2022 14:00
Onsite Hours :04:00
Name of the Project : Barnett Shoals Road Development
Project Location :Watkinsville
Weather :suny
Departure Time :10/28/2022 18:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
10/28/2022 | 1 | 25.4 | 102.4 | P-2 | 99.5 | 22.1 | 102.9 | 95 | D6938 | Pass |
Location : | in the north of keyway , Elv/Depth :-9' from top of keyway | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
10/28/2022 | 2 | 23.1 | 104.1 | P-2 | 99.5 | 22.1 | 104.6 | 95 | D6938 | Pass |
Location : | in the south of keyway , Elv/Depth :-9' from top of keyway | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
10/28/2022 | 3 | 24.4 | 102.5 | P-2 | 99.5 | 22.1 | 103.0 | 95 | D6938 | Pass |
Location : | in keyway, Elv/Depth :-9' from top of keyway | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
10/28/2022 | 4 | 25 | 102.2 | P-2 | 99.5 | 22.1 | 102.7 | 95 | D6938 | Pass |
Location : | in keyway, Elv/Depth :-9' from top of keyway | |||||||||
Comment : | Gauge Serial No. :29588 |
Technician Signature / DateAminullah Azimi, October 28, 2022
Reviewer Name / DateRamchandra Mogulla, November 11, 2022