Skip to content

Density Test Report

Date :10/21/2022
Project No :2022C135
Client Company :Mark Spain
Arrival Time : 8:30
Onsite Hours :03:30
Name of the Project : Barnett Shoals Road Development
Project Location :Watkinsville
Weather :suny
Departure Time : 12:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/21/2022 1 25 96.4 P-1 97.3 23.7 99.1 95 D6938 Pass
Location : along dam keyway, Elv/Depth :-15 feet from top of keyway
Comment : Gauge Serial No. :29588
10/21/2022 2 21.1 101.8 P-4 102.8 21.5 99.0 95 D6938 Pass
Location : South side of keyway , Elv/Depth :-24 feet from top of keyway
Comment : Gauge Serial No. :29588
10/21/2022 3 24.1 96.0 P-1 97.3 23.7 98.7 95 D6938 Pass
Location : North side of keyway , Elv/Depth :-24 feet from top of keyway
Comment : Gauge Serial No. :29588
Technician Signature / DateAminullah Azimi, October 21, 2022
Reviewer Name / DateKenneth Mosman, October 23, 2022