- Home
- Concrete Test Report Report ID: 55284
- This project is inactive from admin.Download Report
Concrete Test Report
Date :08/17/2022
Project No :2022C186
Client Company :Excellere
Arrival Time :08/17/2022 08:00
Onsite Hours :04:00
Name of the Project :Midblock Crosswalks
Project Location :Alpharetta
Weather :Clear and Sunny
Departure Time :08/17/2022 12:00
ASEC Technician Name :Rasheen Biggins
Concrete Placement Information
Location(S):
Testing:
1 Set of concrete specimens (5 Cylinders per set) were cast during the cast-in-place concrete pour at the above referenced location, in accordance with ASTM C31. The cylinders will remain on site for the initial 24-48 hrs curing.
Compliance:
Field placement of concrete appeared to be in accordance with the project specifications (i.e., slump, temperature, etc) (refer to remarks below)
Deviations and/or noncompliances were noted during the field placement (refer to remarks below)
Cylinders
Pick Up: 1 Sets of concrete cylinders/ 5 cylinders per set were picked up & transported to AS Engineering and Consulting LLC (ASEC) for curing and testing in accordance with ASTM C39, C670/1231
Pick Up: 1 Sets of concrete cylinders/ 5 cylinders per set were picked up & transported to AS Engineering and Consulting LLC (ASEC) for curing and testing in accordance with ASTM C39, C670/1231
Field Curing:
Cylinders were stored for the initial 24 hours
Near the poured structure
In an insulated curing box
Other
Remarks:
Unit Weight of Concrete tested on this day: 146.8 pcf.
Placement Location: 1009 Mid Broadwell Road, Alpharetta, GA
Field Test Data
Set Number :2022ASEC003
Date Sampled :08/17/2022
Sampled By :Rasheen Biggins
Contractor :Excellere Construction
Truck Number :
Time Batched :
Location of Placement :1009 Mid Broadwell Road, Alpharetta, GA
Number of samples cast :5
Ambient Temperature (°f) :85
Slump (in.) :5
Water added (gal.) :
Laboratory Number :
Time Sampled :10:00
Weather Condition :Clear and Sunny
Concrete Supplier :USA Ready Mix
Mix ID :
Quantity of Load (cu. yd.) :
Sample Cast :1
Specified Strength :3000
Concrete Temperature(°f) :76
Air Content (%) :6.3
Strength Test Results
Specimen Number | Age (days) | Date Tested | Dia(in.) | Area (sq in.) | Maximum Loads (lbs) | Strength (lbs) | % Design Strength | Type of Fracture |
---|
UNLESS OTHERWISE SPECIFIED, TESTS WERE PERFORMED IN ACCORDANCE WITH ASTM TEST METHODS C31, C39, C138, C143, C173, AND C1064. FRACTURE TYPE INDICATED BY NUMBER.
(Type 1) Cone (Type 2) Cone-split (Type 3) Vertical (Type 4) Shear (Type 5) Edge Fracture (Type 6) Pointed
Technician Signature / DateRasheen Biggins, August 17, 2022
Reviewer Name / DateRamchandra Mogulla, February 22, 2023