Skip to content

Density Test Report

Date :11/02/2022
Project No :2022C135
Client Company :Mark Spain
Arrival Time :11/02/2022 11:30
Onsite Hours :06:30
Name of the Project : Barnett Shoals Road Development
Project Location :Watkinsville
Weather :cloudy
Departure Time :11/02/2022 18:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/02/2022 1 24.2 98.3 P-1 97.3 23.7 101.0 95 D6938 Pass
Location : in the North side of keyway , Elv/Depth :-8.5' from top of keyway
Comment : Gauge Serial No. :29588
11/02/2022 2 26.4 97.4 P-1 97.3 23.7 100.1 95 D6938 Pass
Location : in the south side of keyway, Elv/Depth :-8' from top of keyway
Comment : Gauge Serial No. :29588
11/02/2022 3 25.1 94.2 P-1 97.3 23.7 96.8 95 D6938 Pass
Location : in the north of keyway , Elv/Depth :-8' from top of keyway
Comment : Gauge Serial No. :29588
11/02/2022 4 25.7 96.6 P-1 97.3 23.7 99.3 95 D6938 Pass
Location : in keyway, Elv/Depth :-8' from top of keyway
Comment : Gauge Serial No. :29588
11/02/2022 5 25.1 97.8 P-1 97.3 23.7 100.5 95 D6938 Pass
Location : in keyway , Elv/Depth :-8' from top of keyway
Comment : Gauge Serial No. :29588
Technician Signature / DateAminullah Azimi, November 2, 2022
Reviewer Name / DateKenneth Mosman, November 13, 2022