- Home
- Density Test Report Report ID: 55456
- Edit Download Report
Density Test Report
Date :11/07/2022
Project No :2022C165
Client Company :Toll Bros. Inc.
Arrival Time :11/07/2022 08:00
Onsite Hours :07:00
Name of the Project :Northfield @ Polo Fields - Phase2
Project Location :Pittman Road, Cumming, GA
Weather :sunny
Departure Time :11/07/2022 15:00
ASEC Technician Name :Vidal Dias
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
11/07/2022 | Test 1 | 17.9 | 87.3 | 3 | 99.4 | 21.3 | 87.8 | 95 | D6938 | Fail |
Location : | see attached photos in Daily Field Report, Elv/Depth :1068.7 | |||||||||
Comment : | This area requires scarification and recompaction prior to retesting. | Gauge Serial No. : | ||||||||
11/07/2022 | Test 2 | 20.1 | 103.1 | 3 | 99.4 | 21.3 | 103.7 | 95 | D6938 | Pass |
Location : | see attached photos in Daily Field Report, Elv/Depth :1070 | |||||||||
Comment : | Gauge Serial No. : | |||||||||
11/07/2022 | test 3 | 19.7 | 85.6 | 3 | 99.4 | 21.3 | 86.1 | 95 | D6938 | Fail |
Location : | see attached photos in Daily Field Report, Elv/Depth :1070 | |||||||||
Comment : | This area requires scarification and recompaction prior to retesting. | Gauge Serial No. : |
Technician Signature / DateVidal Dias, November 7, 2022
Reviewer Name / DateKenneth Mosman, April 07, 2023