- Home
- Density Test Report Report ID: 55554
- This project is inactive from admin.Download Report
Density Test Report
Date :06/03/2022
Project No :2022C128
Client Company :Century
Arrival Time :06/03/2022 07:30
Onsite Hours :05:30
Name of the Project :Sidney Square, Flowery Branch
Project Location :Flowery Branch
Weather :
Departure Time :06/03/2022 13:00
ASEC Technician Name :Rasheen Biggins
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
06/03/2022 | 1 | 29.1 | 89.2 | 2 | 92.8 | 22.3 | 96.1 | 95 | D6938 | Pass |
Location : | Near wall, Elv/Depth : | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
06/03/2022 | 2 | 28.4 | 89.6 | 2 | 92.8 | 22.3 | 96.6 | 95 | D6938 | Pass |
Location : | Near wall, Elv/Depth : | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
06/03/2022 | 3 | 24.1 | 89.6 | 2 | 92.8 | 22.3 | 96.6 | 95 | D6938 | Pass |
Location : | Shoulder of roadway, Elv/Depth : | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
06/03/2022 | 4 | 25.5 | 95.8 | 1 | 100 | 20.3 | 95.8 | 95 | D6938 | Pass |
Location : | Shoulder of roadway, Elv/Depth : | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
06/03/2022 | 5 | 28.3 | 94.5 | 2 | 92.8 | 22.3 | 101.8 | 95 | D6938 | Pass |
Location : | Shoulder of roadway, Elv/Depth : | |||||||||
Comment : | Gauge Serial No. :38069 |
Technician Signature / DateRasheen Biggins, June 3, 2022
Reviewer Name / DateKenneth Mosman, November 13, 2022