Skip to content

Density Test Report

Date :11/09/2022
Project No :2022C135
Client Company :Mark Spain
Arrival Time :11/09/2022 14:00
Onsite Hours :03:30
Name of the Project : Barnett Shoals Road Development
Project Location :Watkinsville
Weather :cloudy
Departure Time :11/09/2022 17:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/09/2022 1 22.1 106.0 P-2 99.5 22.1 106.5 95 D6938 Pass
Location : North of keyway , Elv/Depth :-5.5 from top of keyway
Comment : Gauge Serial No. :85751
11/09/2022 2 23.9 100.6 P-2 99.5 22.1 101.1 95 D6938 Pass
Location : in keyway, Elv/Depth :-4.5' from top of keyway
Comment : Gauge Serial No. :85751
11/09/2022 3 25.5 99.7 P-2 99.5 22.1 100.2 95 D6938 Pass
Location : South of keyway, Elv/Depth :-5.5' from top of keyway
Comment : Gauge Serial No. :85751
11/09/2022 4 21.3 104.4 P-2 99.5 22.1 104.9 95 D6938 Pass
Location : South of keyway, Elv/Depth :-5' from top of keyway
Comment : Gauge Serial No. :85751
11/09/2022 5 24.5 101.1 P-2 99.5 22.1 101.6 95 D6938 Pass
Location : in keyway, Elv/Depth :-4' from top of keyway
Comment : Gauge Serial No. :85751
Technician Signature / DateAminullah Azimi, November 9, 2022
Reviewer Name / DateKenneth Mosman, November 13, 2022