- Home
- Density Test Report Report ID: 55582
- This project is inactive from admin.Download Report
Density Test Report
Date :11/10/2022
Project No :2022C136
Client Company :Century
Arrival Time :11/10/2022 7:00
Onsite Hours :05:00
Name of the Project :Logan Pointe
Project Location :Loganville
Weather :cloudy
Departure Time :11/10/2022 12:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 11/10/2022 | 1 | 29 | 81.6 | P-3 | 96.5 | 22.2 | 84.6 | 95 | D6938 | Fail |
| Location : | Lot #62, Elv/Depth :-1' from finish grade | |||||||||
| Comment : | Recompaction and retesting required. Sheeps-foot roller presently not available for compaction. | Gauge Serial No. :85759 | ||||||||
| 11/10/2022 | 2 | 26.8 | 83.4 | P-3 | 96.5 | 22.2 | 86.4 | 90 | D6938 | Fail |
| Location : | Lot #58, Elv/Depth :-1' from finish grade | |||||||||
| Comment : | Recompaction and retesting required. Sheeps-foot roller presently not available for compaction. | Gauge Serial No. :85759 | ||||||||
Technician Signature / DateAminullah Azimi, November 10, 2022
Reviewer Name / DateKenneth Mosman, November 13, 2022