Skip to content

Density Test Report

Date :11/10/2022
Project No :2022C136
Client Company :Century
Arrival Time :11/10/2022 7:00
Onsite Hours :05:00
Name of the Project :Logan Pointe
Project Location :Loganville
Weather :cloudy
Departure Time :11/10/2022 12:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/10/2022 1 29 81.6 P-3 96.5 22.2 84.6 95 D6938 Fail
Location : Lot #62, Elv/Depth :-1' from finish grade
Comment : Recompaction and retesting required. Sheeps-foot roller presently not available for compaction. Gauge Serial No. :85759
11/10/2022 2 26.8 83.4 P-3 96.5 22.2 86.4 90 D6938 Fail
Location : Lot #58, Elv/Depth :-1' from finish grade
Comment : Recompaction and retesting required. Sheeps-foot roller presently not available for compaction. Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, November 10, 2022
Reviewer Name / DateKenneth Mosman, November 13, 2022