Skip to content

Density Test Report

Date :01/14/2023
Project No :2021C002
Client Company :CW Matthews
Arrival Time :01/14/2023 7:30
Onsite Hours :06:00
Name of the Project :Runway 9L End Around Taxiway
Project Location :HJAIA
Weather :cloudy
Departure Time :01/14/2023 13:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
01/14/2023 1 9.5 116.9 9 120.8 11.3 96.8 95 D6938 Pass
Location : STA 7003+56, Elv/Depth :-2 feet from finish grade
Comment : Gauge Serial No. :85759
01/14/2023 2 9.8 114.9 9 120.8 11.3 95.1 95 D6938 Pass
Location : STA 7003+34, Elv/Depth :- 2 feet from finish grade
Comment : Gauge Serial No. :85759
01/14/2023 3 11.5 116.0 9 120.8 11.3 96.0 95 D6938 Pass
Location : STA 7003+13, Elv/Depth :-2 feet from finish grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, January 14, 2023
Reviewer Name / DateRamchandra Mogulla, January 18, 2023