- Home
- Density Test Report Report ID: 56104
- Edit Download Report
Density Test Report
Date :01/14/2023
Project No :2021C002
Client Company :CW Matthews
Arrival Time :01/14/2023 7:30
Onsite Hours :06:00
Name of the Project :Runway 9L End Around Taxiway
Project Location :HJAIA
Weather :cloudy
Departure Time :01/14/2023 13:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
01/14/2023 | 1 | 9.5 | 116.9 | 9 | 120.8 | 11.3 | 96.8 | 95 | D6938 | Pass |
Location : | STA 7003+56, Elv/Depth :-2 feet from finish grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
01/14/2023 | 2 | 9.8 | 114.9 | 9 | 120.8 | 11.3 | 95.1 | 95 | D6938 | Pass |
Location : | STA 7003+34, Elv/Depth :- 2 feet from finish grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
01/14/2023 | 3 | 11.5 | 116.0 | 9 | 120.8 | 11.3 | 96.0 | 95 | D6938 | Pass |
Location : | STA 7003+13, Elv/Depth :-2 feet from finish grade | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, January 14, 2023
Reviewer Name / DateRamchandra Mogulla, January 18, 2023