- Home
- Density Test Report Report ID: 56247
- Edit Download Report
Density Test Report
Date :01/10/2023
Project No :2022C227
Client Company :Artisan
Arrival Time :01/10/2023 08:00
Onsite Hours :08:00
Name of the Project :Riverwalk Manor (CMT) Unit 2, PH 4E and 4F
Project Location :Dallas
Weather :Sunny
Departure Time :01/10/2023 16:00
ASEC Technician Name :Vidal Dias
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
01/10/2023 | 1 | 20 | 89.2 | P-01 | 100.4 | 18.6 | 88.8 | 90 | D6938 | Fail |
Location : | (see attached photos in Daily Report), Elv/Depth : | |||||||||
Comment : | Gauge Serial No. : | |||||||||
01/10/2023 | 2 | 19.5 | 91.2 | P-01 | 100.4 | 18.6 | 90.8 | 90 | D6938 | Pass |
Location : | (see attached photos in Daily Report), Elv/Depth : | |||||||||
Comment : | Gauge Serial No. : |
Technician Signature / DateVidal Dias, January 10, 2023
Reviewer Name / DateKenneth Mosman, January 29, 2023