Skip to content

Density Test Report

Date :02/09/2023
Project No :2022C227
Client Company :Artisan
Arrival Time :02/09/2023 13:00
Onsite Hours :05:00
Name of the Project :Riverwalk Manor (CMT) Unit 2, PH 4E and 4F
Project Location :Dallas
Weather :cloudy
Departure Time :02/09/2023 18:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/09/2023 1 16.1 116.5 P-01 100.4 18.6 99.9 90 D6938 Pass
Location : Lot #422, Elv/Depth :-6.5' from finished grade
Comment : Gauge Serial No. :85759
02/09/2023 2 15.9 97.8 P-01 100.4 18.6 97.4 90 D6938 Pass
Location : at roadway, Elv/Depth :-3.5' from finished grade
Comment : Gauge Serial No. :85759
02/09/2023 3 16 93.9 P-01 100.4 18.6 93.5 90 D6938 Pass
Location : Lot #426, Elv/Depth :-4.5' from finished grade
Comment : Gauge Serial No. :85759
02/09/2023 4 17.5 95.0 P-01 100.4 18.6 94.6 90 D6938 Pass
Location : at roadway, Elv/Depth :-9' from finished grade
Comment : Gauge Serial No. :85759
02/09/2023 5 16 94.8 P-01 100.4 18.6 94.4 90 D6938 Pass
Location : Lot #424, Elv/Depth :-3.5' from finished grade
Comment : Gauge Serial No. :85759
02/09/2023 6 16.2 117.0 P-01 100.4 18.6 100.3 90 D6938 Pass
Location : Lot #423, Elv/Depth :-7.5' from finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, February 9, 2023
Reviewer Name / DateKenneth Mosman, February 12, 2023