Skip to content

Density Test Report

Date :02/10/2023
Project No :2022C136
Client Company :Century
Arrival Time :02/10/2023 9:30
Onsite Hours :02:00
Name of the Project :Logan Pointe
Project Location :Loganville
Weather :cloudy
Departure Time :02/10/2023 11:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/10/2023 1 27.7 97.9 P-1 99.0 21.4 98.9 90 D6938 Pass
Location : Lot #35, Elv/Depth :at finished grade
Comment : Moisture excessed from specified limit. Gauge Serial No. :85759
02/10/2023 2 27.9 99.7 P-1 99.0 21.4 100.7 90 D6938 Pass
Location : Lot #36, Elv/Depth :at finished grade
Comment : Moisture excessed from specified limit. Gauge Serial No. :85759
02/10/2023 3 27.1 98.2 P-1 99.0 21.4 99.2 90 D6938 Pass
Location : Lot #38, Elv/Depth :at finished grade
Comment : Moisture excessed from specified limit. Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, February 10, 2023
Reviewer Name / DateKenneth Mosman, February 12, 2023