Density Test Report

Date :02/10/2023
Project No :2022C227
Client Company :Artisan
Arrival Time :02/10/2023 13:00
Onsite Hours :05:00
Name of the Project :Riverwalk Manor (CMT) Unit 2, PH 4E and 4F
Project Location :Dallas
Weather :cloudy
Departure Time :02/10/2023 18:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/10/2023 1 17.1 98.0 P-01 100.4 18.6 97.6 90 D6938 Pass
Location : Lot #422, Elv/Depth :-5' from finished grade
Comment : Gauge Serial No. :85759
02/10/2023 2 16.3 98.4 P-01 100.4 18.6 98.0 90 D6938 Pass
Location : at roadway, Elv/Depth :-1' from finished grade
Comment : Gauge Serial No. :85759
02/10/2023 3 19.7 99.8 P-01 100.4 18.6 99.4 90 D6938 Pass
Location : Lot #426, Elv/Depth :-3.5' from finished grade
Comment : Gauge Serial No. :85759
02/10/2023 4 20.1 97.7 P-01 100.4 18.6 97.3 90 D6938 Pass
Location : at roadway, Elv/Depth :-8' from finished grade
Comment : Gauge Serial No. :85759
02/10/2023 5 15.7 96.8 P-01 100.4 18.6 96.4 90 D6938 Pass
Location : Lot #424, Elv/Depth :-1' from finished grade
Comment : Gauge Serial No. :85759
02/10/2023 6 15.3 97.6 P-01 100.4 18.6 97.2 90 D6938 Pass
Location : Lot #423, Elv/Depth :-5.5' from finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, February 10, 2023
Reviewer Name / DateKenneth Mosman, February 12, 2023