Skip to content

Density Test Report

Date :02/20/2023
Project No :2022C227
Client Company :Artisan
Arrival Time :02/20/2023 9:00
Onsite Hours :08:00
Name of the Project :Riverwalk Manor (CMT) Unit 2, PH 4E and 4F
Project Location :Dallas
Weather :cloudy
Departure Time :02/20/2023 17:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/20/2023 1 16.6 96.1 P-01 100.4 18.6 95.7 90 D6938 Pass
Location : Lot #403, Elv/Depth :at finished grade
Comment : Gauge Serial No. :85759
02/20/2023 2 16.6 96.8 P-01 100.4 18.6 96.4 90 D6938 Pass
Location : Lot #402, Elv/Depth :at finished grade
Comment : Gauge Serial No. :85759
02/20/2023 3 17.1 92.1 P-01 100.4 18.6 91.7 90 D6938 Pass
Location : Lot #404, Elv/Depth :- 1 foot from finished grade
Comment : Gauge Serial No. :85759
02/20/2023 4 16.8 99.6 P-01 100.4 18.6 99.2 90 D6938 Pass
Location : Lot #404, Elv/Depth :at finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, February 20, 2023
Reviewer Name / DateKenneth Mosman, March 14, 2023