Skip to content

Density Test Report

Date :03/07/2023
Project No :2022C135
Client Company :Mark Spain
Arrival Time :03/07/2023 8:30
Onsite Hours :03:00
Name of the Project : Barnett Shoals Road Development
Project Location :Watkinsville
Weather :Sunny
Departure Time :03/07/2023 11:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
03/07/2023 1 26 100.4 P-1 97.3 23.7 103.2 95 D6938 Pass
Location : at keyway , Elv/Depth :at finished grade
Comment : Gauge Serial No. :85759
03/07/2023 2 26.9 99.6 P-1 97.3 23.7 102.4 95 D6938 Pass
Location : at keyway, Elv/Depth :at finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, March 7, 2023
Reviewer Name / DateKenneth Mosman, March 14, 2023