Skip to content

Density Test Report

Date :03/13/2023
Project No :2022C235
Client Company :Jackson Demolition Service, Inc.
Arrival Time :03/13/2023 06:00
Onsite Hours :10:30
Name of the Project :Plant Gorgas Demolition and Grading
Project Location :460 Gorgas Rd, Parrish, AL 35580
Weather :Sunny
Departure Time :03/13/2023 16:30
ASEC Technician Name :Vidal Dias

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
03/13/2023 1 5 140.0 44789 131.9 9.5 101.1 D6938 Pass
Location : C6, Elv/Depth :277
Comment : Gauge Serial No. :
03/13/2023 Test 2 3.1 145.1 44789 131.9 9.5 106.7 D6938 Pass
Location : B6, Elv/Depth :276
Comment : Gauge Serial No. :
03/13/2023 Test 3 3.2 152.5 44789 131.9 9.5 115.6 D6938 Pass
Location : H6 near the boundary of G6, Elv/Depth :276
Comment : Gauge Serial No. :
03/13/2023 Test 4 4 148.5 44789 131.9 9.5 108.3 D6938 Pass
Location : F6, Elv/Depth :276
Comment : Gauge Serial No. :
Technician Signature / DateVidal Dias, March 13, 2023
Reviewer Name / DateKenneth Mosman, April 02, 2023