Skip to content

Density Test Report

Date :03/28/2023
Project No :2022C235
Client Company :Jackson Demolition Service, Inc.
Arrival Time :03/28/2023 06:00
Onsite Hours :10:00
Name of the Project :Plant Gorgas Demolition and Grading
Project Location :460 Gorgas Rd, Parrish, AL 35580
Weather :Partly Cloudy
Departure Time :03/28/2023 16:00
ASEC Technician Name :Vidal Dias

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
03/28/2023 1 12.6 120.9 ASEC-2 110.9 15.3 109.0 90 D6938 Pass
Location : Section 1 of basement , Elv/Depth :247
Comment : Gauge Serial No. :30942
03/31/2023 2 15.8 114.9 ASEC-2 110.9 15.3 103.6 90 D6938 Pass
Location : Section 2 of basement , Elv/Depth :244
Comment : Gauge Serial No. :30942
Technician Signature / DateVidal Dias, March 28, 2023
Reviewer Name / DateRamchandra Mogulla, April 24, 2023