- Home
- Density Test Report Report ID: 58647
- Edit Download Report
Density Test Report
Date :04/17/2023
Project No :2022C165
Client Company :Toll Bros. Inc.
Arrival Time :04/17/2023 9:00
Onsite Hours :08:30
Name of the Project :Northfield @ Polo Fields - Phase2
Project Location :Pittman Road, Cumming, GA
Weather :sunny
Departure Time :04/17/2023 17:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
04/17/2023 | 1 | 32.1 | 84.9 | 5 | 93.8 | 20.9 | 90.5 | 90 | D6938 | Pass |
Location : | 13 feet to m NE of MHAA80., Elv/Depth :6 feet below finish grade | |||||||||
Comment : | Moisture is exceeded from specified limit range. | Gauge Serial No. :85759 | ||||||||
04/17/2023 | 2 | 30.3 | 87.6 | 5 | 93.8 | 20.9 | 93.4 | 90 | D6938 | Pass |
Location : | 22 feet to SW of MH AA80., Elv/Depth :4 feet below finish grade | |||||||||
Comment : | Moisture is exceeded from specified limit range. | Gauge Serial No. :85759 | ||||||||
04/17/2023 | 3 | 30.1 | 84.9 | 5 | 93.8 | 20.9 | 90.5 | 90 | D6938 | Pass |
Location : | 30 feet to NE of MH AA70., Elv/Depth :4 feet below finish grade | |||||||||
Comment : | Moisture is exceeded from specified limit range. | Gauge Serial No. :85759 | ||||||||
04/17/2023 | 4 | 30.2 | 84.6 | 5 | 93.8 | 20.9 | 90.2 | 90 | D6938 | Pass |
Location : | 17 feet to NE of MH AA80, Elv/Depth :5 feet below finish grade | |||||||||
Comment : | Moisture is exceeded from specified limit range. Multiple tests were performed to verify compaction. | Gauge Serial No. :85759 | ||||||||
04/17/2023 | 5 | 30.1 | 84.7 | 5 | 93.8 | 20.9 | 90.3 | 90 | D6938 | Pass |
Location : | 33 feet to SW of MH AA80., Elv/Depth :3 feet below finish grade | |||||||||
Comment : | Moisture is exceeded from specified limit range. | Gauge Serial No. :85759 | ||||||||
04/17/2023 | 6 | 33 | 85.7 | 5 | 93.8 | 20.9 | 91.4 | 90 | D6938 | Pass |
Location : | 47 feet to NE of MH AA70, Elv/Depth :2.5 feet below finish grade | |||||||||
Comment : | Moisture is exceeded from specified limit range. | Gauge Serial No. :85759 | ||||||||
04/17/2023 | 7 | 32 | 84.8 | 5 | 93.8 | 20.9 | 90.4 | 90 | D6938 | Pass |
Location : | 13 feet to NE of MH AA80., Elv/Depth :4.5 feet below finish grade | |||||||||
Comment : | Moisture is exceeded from specified limit range. Multiple tests were performed to verify compaction. | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, April 17, 2023
Reviewer Name / DateRamchandra Mogulla, April 21, 2023