- Home
- Density Test Report Report ID: 58952
- This project is inactive from admin.Download Report
Density Test Report
Date :05/01/2023
Project No :2022C235
Client Company :Jackson Demolition Service, Inc.
Arrival Time :05/01/2023 06:00
Onsite Hours :10:30
Name of the Project :Plant Gorgas Demolition and Grading
Project Location :460 Gorgas Rd, Parrish, AL 35580
Weather :SUNNY
Departure Time :05/01/2023 16:30
ASEC Technician Name :Avinash Bandham
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
05/01/2023 | 1 | 15.2 | 102.8 | 43409 | 107.5 | 17.8 | 95.6 | 90 | D6938 | Pass |
Location : | Section-2 Basement area G7, Elv/Depth :246.83 | |||||||||
Comment : | Test-1 performed in the Section-2 of the basement are G7 positioned at 66ft from east end wall and 102ft from the south end wall. | Gauge Serial No. :30942 | ||||||||
05/01/2023 | 2 | 15.8 | 106.0 | 43409 | 107.5 | 17.8 | 98.6 | 90 | D6938 | Pass |
Location : | section-2 basement area G7, Elv/Depth :246.83 | |||||||||
Comment : | Test-2 performed in the Section-2 of the basement are G7 positioned at 100ft from east end wall and 94ft from the south end wall. | Gauge Serial No. :30942 | ||||||||
05/01/2023 | 3 | 18.8 | 106.6 | 43409 | 107.5 | 17.8 | Check | |||
Location : | Section-2 Basement area G7, Elv/Depth :246.83 | |||||||||
Comment : |
Technician Signature / DateAvinash Bandham, May 1, 2023
Reviewer Name / DateRamchandra Mogulla, May 02, 2023