Density Test Report

Date :05/01/2023
Project No :2022C165
Client Company :Toll Bros. Inc.
Arrival Time :05/01/2023 9:30
Onsite Hours :05:00
Name of the Project :Northfield @ Polo Fields - Phase2
Project Location :Pittman Road, Cumming, GA
Weather :sunny
Departure Time :05/01/2023 14:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
05/01/2023 1 25.8 98.9 3 99.4 21.3 99.5 90 D6938 Pass
Location : 167 feet to NE of MH BB10., Elv/Depth :2 feet below finished grade
Comment : Moisture content exceeded specified limit range. Gauge Serial No. :85759
05/01/2023 2 24.9 97.8 3 99.4 21.3 98.4 90 D6938 Pass
Location : 127 feet to SW of MH BB20., Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :85759
05/01/2023 3 27.5 92.2 3 99.4 21.3 92.8 90 D6938 Pass
Location : 85 feet to SW of MH BB20., Elv/Depth :4 feet below finished grade
Comment : Moisture content exceeded specified limit range. Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, May 1, 2023
Reviewer Name / DateKenneth Mosman, May 07, 2023