- Home
- Density Test Report Report ID: 59397
- This project is inactive from admin.Download Report
Density Test Report
Date :05/19/2023
Project No :2022C113
Client Company :CWM
Arrival Time :05/19/2023 8:00
Onsite Hours :04:00
Name of the Project :Airfield Sewer Enhancements
Project Location :HJAIA
Weather :cloudy
Departure Time :05/19/2023 12:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
05/19/2023 | 1 | 7.3 | 122.1 | Recycled GAB | 134.9 | 8.7 | 90.5 | 90 | D6938 | Pass |
Location : | 35 feet to west of MH3, Elv/Depth :8 inches finish grade | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, May 19, 2023
Reviewer Name / DateRamchandra Mogulla, July 10, 2023