- Density Test Report Report ID: 59413
- Edit Download Report
Density Test Report
Date :05/23/2023
Project No :2023C111
Client Company :2MATL
Arrival Time :05/24/2023 01:30
Onsite Hours :04:00
Name of the Project :DOA Fiber Infrastructure Improvements
Project Location :HJAIA
Weather :overcast
Departure Time :05/24/2023 05:30
ASEC Technician Name :Isaac Davis
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
05/24/2023 | 1 | 10.3 | 115.1 | M10 | 119.0 | 11.4 | 96.7 | 90 | D6938 | Pass |
Location : | DOA 17A, Elv/Depth :Approximately -2 feet below grade | |||||||||
Comment : | Gauge Serial No. : | |||||||||
05/24/2023 | 2 | 3.4 | 117.1 | M10 | 119.0 | 11.4 | 98.4 | 95 | D6938 | Pass |
Location : | DOA 17A, Elv/Depth :Approximately -1 foot below grade | |||||||||
Comment : | Gauge Serial No. : | |||||||||
05/24/2023 | 2R | 6.4 | 115.7 | M10 | 119.0 | 11.4 | 97.2 | 95 | D6938 | Pass |
Location : | DOA 17A, Elv/Depth :Approximately -1 foot below grade | |||||||||
Comment : | Gauge Serial No. : | |||||||||
05/24/2023 | 3 | 7 | 113.5 | M10 | 119.0 | 11.4 | 95.4 | 95 | D6938 | Pass |
Location : | DOA 17A, Elv/Depth :Approximately - 6 inches below grade | |||||||||
Comment : | Gauge Serial No. : |
Technician Signature / DateIsaac Davis, May 23, 2023
Reviewer Name / DateKenneth Mosman, July 08, 2023