Skip to content

Density Test Report

Date :05/24/2023
Project No :2022C227
Client Company :Artisan
Arrival Time :05/24/2023 9:00
Onsite Hours :07:00
Name of the Project :Riverwalk Manor (CMT) Unit 2, PH 4E and 4F
Project Location :Dallas
Weather :sunny
Departure Time :05/24/2023 16:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
05/24/2023 1 25.4 90.8 P-03(23568) 100.8 21.4 90.1 90 D6938 Pass
Location : road in the front of lot 417, Elv/Depth :17 feet below finish grade
Comment : Gauge Serial No. :85759
05/24/2023 2 30.1 90.6 P-02 100.6 20.9 90.1 90 D6938 Pass
Location : lot 417, Elv/Depth :17 feet below finish grade
Comment : test result on hold for proctor Gauge Serial No. :85759
05/24/2023 3 27.3 91.0 P-01 100.4 18.6 90.6 90 D6938 Pass
Location : lot 416, Elv/Depth :10.5 feet below finish grade
Comment : Gauge Serial No. :85759
05/24/2023 4 28.4 87.0 P-01 100.4 18.6 86.7 D6938 Pass
Location : lot 417, Elv/Depth :5 feet below finish grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, May 24, 2023
Reviewer Name / DateRamchandra Mogulla, September 14, 2023