Skip to content

Density Test Report

Date :05/31/2023
Project No :2022C113
Client Company :CWM
Arrival Time :05/31/2023 7:00
Onsite Hours :05:30
Name of the Project :Airfield Sewer Enhancements
Project Location :HJAIA
Weather :sunny
Departure Time :05/31/2023 12:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
05/31/2023 1 3.5 134.5 GAB 23411 140.2 5.7 95.9 95 D6938 Pass
Location : between MH3 and MH9 or 20 feet to East of MH 3, Elv/Depth :at finished grade
Comment : Gauge Serial No. :85759
05/31/2023 2 2.5 133.3 GAB 23411 140.2 5.7 95.1 95 D6938 Pass
Location : 15 feet to north of MH 3, Elv/Depth :at finished grade
Comment : Gauge Serial No. :85759
05/31/2023 3 2.9 133.4 GAB 23411 140.2 5.7 95.1 95 D6938 Pass
Location : 33 feet to South of MH 10, Elv/Depth :at finished grade
Comment : Gauge Serial No. :85759
05/31/2023 4 3.1 129.4 Recycled GAB 134.9 8.7 95.9 95 D6938 Pass
Location : between MH 1 and MH 2 under the road, Elv/Depth :at finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, May 31, 2023
Reviewer Name / DateKenneth Mosman, July 08, 2023