Density Test Report
Date :06/09/2023
Project No :2022C227
Client Company :Artisan
Arrival Time :06/09/2023 8:00
Onsite Hours :03:30
Name of the Project :Riverwalk Manor (CMT) Unit 2, PH 4E and 4F
Project Location :Dallas
Weather :sunny
Departure Time :06/09/2023 11:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
06/09/2023 | 1 | 14.6 | 91.7 | P-03(23568) | 100.8 | 21.4 | 91.0 | 90 | D6938 | Pass |
Location : | Lot 417, Elv/Depth :at finished grade | |||||||||
Comment : | In-situ moisture content was lower than specified limit of -3 to +2 of Optimum Moisture Content | Gauge Serial No. :85759 | ||||||||
06/09/2023 | 2 | 16.1 | 95.3 | P-03(23568) | 100.8 | 21.4 | 94.5 | 90 | D6938 | Pass |
Location : | Lot 416, Elv/Depth :at finished grade | |||||||||
Comment : | In-situ moisture content was lower than specified limit of -3 to +2 of Optimum Moisture Content | Gauge Serial No. :85759 | ||||||||
06/09/2023 | 3 | 21 | 91.6 | P-03(23568) | 100.8 | 21.4 | 90.9 | 90 | D6938 | Pass |
Location : | Lot 412, Elv/Depth :at finished grade | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, June 9, 2023
Reviewer Name / DateKenneth Mosman, July 08, 2023