- Home
- Density Test Report Report ID: 60640
- Edit Download Report
Density Test Report
Date :07/31/2023
Project No :2023C144
Client Company :CCG
Arrival Time :07/31/2023 08:00
Onsite Hours :10:00
Name of the Project :Carodel Farms @ Union Church Rd
Project Location :Flowery Branch
Weather :Cloudy
Departure Time :07/31/2023 18:00
ASEC Technician Name :Vidal Shengan
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
07/31/2023 | 1 | 28.9 | 86.3 | P-1 | 96.5 | 22.3 | 89.4 | 92 | D6938 | Fail |
Location : | Lot 39, Elv/Depth :1 foot below finished grade | |||||||||
Comment : | In-situ moisture contents well above optimum moisture content | Gauge Serial No. :3430 | ||||||||
07/31/2023 | 2 | 21.2 | 96.6 | P-1 | 96.5 | 22.3 | 100.1 | 98 | D6938 | Pass |
Location : | Lot 40, Elv/Depth :1 foot below finished grade | |||||||||
Comment : | Gauge Serial No. :3430 | |||||||||
07/31/2023 | 3 | 21.9 | 91.1 | P-1 | 96.5 | 22.3 | 94.4 | 95 | D6938 | Fail |
Location : | Lot 41, Elv/Depth :1 foot below finished grade | |||||||||
Comment : | recompactive effort required in this area | Gauge Serial No. :3430 | ||||||||
D6938 | Fail | |||||||||
Location : | , Elv/Depth : | |||||||||
Comment : | Gauge Serial No. : |
Technician Signature / DateVidal Shengan, July 31, 2023
Reviewer Name / DateKenneth Mosman, September 15, 2023