- Concrete Test Report Report ID: 60772
- Edit Download Report
Concrete Test Report
Date :08/10/2023
Project No :2023C111
Client Company :2MATL
Arrival Time :08/10/2023 6:00
Onsite Hours :06:00
Name of the Project :DOA Fiber Infrastructure Improvements
Project Location :HJAIA
Weather :sunny
Departure Time :08/10/2023 12:00
ASEC Technician Name :Aminullah Azimi
Concrete Placement Information
Location(S):
Testing:
A Set of concrete specimens (5 Cylinders per set) were cast during the cast-in-place concrete pour at the above referenced location, in accordance with ASTM C31. The cylinders will remain on site for the initial 24-48 hrs curing.
Compliance:
Field placement of concrete appeared to be in accordance with the project specifications (i.e., slump, temperature, etc) (refer to remarks below)
Deviations and/or noncompliances were noted during the field placement (refer to remarks below)
Cylinders
Pick Up: A Sets of concrete cylinders/ 5 cylinders per set were picked up & transported to AS Engineering and Consulting LLC (ASEC) for curing and testing in accordance with ASTM C39, C670/1231
Pick Up: A Sets of concrete cylinders/ 5 cylinders per set were picked up & transported to AS Engineering and Consulting LLC (ASEC) for curing and testing in accordance with ASTM C39, C670/1231
Field Curing:
Cylinders were stored for the initial 24 hours
Near the poured structure
In an insulated curing box
Other
Remarks:
Field Test Data
Set Number :A
Date Sampled :08/10/2023
Sampled By :Aminullah Azimi
Contractor :
Truck Number :248
Time Batched :6:43
Location of Placement :Vault 1
Number of samples cast :5
Ambient Temperature (°f) :76
Slump (in.) :4
Water added (gal.) :0
Laboratory Number :A
Time Sampled :8:15
Weather Condition :sunny
Concrete Supplier :ERNEST
Mix ID :45CA25
Quantity of Load (cu. yd.) :9
Sample Cast :A
Specified Strength :4500
Concrete Temperature(°f) :87
Air Content (%) :6.7
Strength Test Results
Specimen Number | Age (days) | Date Tested | Dia(in.) | Area (sq in.) | Maximum Loads (lbs) | Strength (lbs) | % Design Strength | Type of Fracture |
---|
UNLESS OTHERWISE SPECIFIED, TESTS WERE PERFORMED IN ACCORDANCE WITH ASTM TEST METHODS C31, C39, C138, C143, C173, AND C1064. FRACTURE TYPE INDICATED BY NUMBER.
(Type 1) Cone (Type 2) Cone-split (Type 3) Vertical (Type 4) Shear (Type 5) Edge Fracture (Type 6) Pointed
Technician Signature / DateAminullah Azimi, August 10, 2023
Reviewer Name / DateKenneth Mosman, September 15, 2023