Skip to content

Density Test Report

Date :08/22/2023
Project No :2023C144
Client Company :CCG
Arrival Time :08/22/2023 8:00
Onsite Hours :05:00
Name of the Project :Carodel Farms @ Union Church Rd
Project Location :Flowery Branch
Weather :sunny
Departure Time :08/22/2023 13:00
ASEC Technician Name :

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
08/22/2023 1 25.3 92.0 P-1 96.5 22.3 95.3 95 D6938 Pass
Location : STA 0+30.00 and 12 feet away from retaining wall, Elv/Depth :2.5 feet below finished grade
Comment : Gauge Serial No. :85759
08/22/2023 2 25.9 92.5 P-1 96.5 22.3 95.9 95 D6938 Pass
Location : STA 0+70.00 and 11 feet away from retaining wall, Elv/Depth :2.5 feet below finished grade
Comment : Gauge Serial No. :85759
08/22/2023 3 26.6 93.4 P-1 96.5 22.3 96.8 95 D6938 Pass
Location : STA 0+50.00, Elv/Depth :1.5 feet below finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, August 22, 2023
Reviewer Name / DateKenneth Mosman, September 17, 2023