Skip to content

Density Test Report

Date :08/22/2023
Project No :2022C227
Client Company :Artisan
Arrival Time :08/22/2023 14:00
Onsite Hours :03:00
Name of the Project :Riverwalk Manor (CMT) Unit 2, PH 4E and 4F
Project Location :Dallas
Weather :sunny
Departure Time :08/22/2023 17:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
08/22/2023 1 16.4 97.6 P-01 100.4 18.6 97.2 95 D6938 Pass
Location : 225 feet to SE of MH 23., Elv/Depth :finish grade
Comment : Gauge Serial No. :85759
08/22/2023 2 15.4 101.3 P-01 100.4 18.6 100.9 95 D6938 Pass
Location : 160 feet to SE of MH 23,, Elv/Depth :@ finish grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, August 22, 2023
Reviewer Name / DateRamchandra Mogulla, September 14, 2023