Date :09/06/2023
Project No :2023C144
Client Company :CCG
Arrival Time :09/06/2023 8:00
Onsite Hours :9:00
Name of the Project :Carodel Farms @ Union Church Rd
Project Location :Flowery Branch
Weather :sunny
Departure Time :09/06/2023 17:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
09/06/2023 1 24.2 96.8 P-1 96.5 22.3 100.3 95 D6938 Pass
Location : Retaining wall STA 1+60.00, Elv/Depth :6 feet below finished grade
Comment : Gauge Serial No. :85759
09/06/2023 2 25.6 97.8 P-1 96.5 22.3 101.3 95 D6938 Pass
Location : Retaining wall STA 2+80.00, Elv/Depth :1.5 feet below finished grade
Comment : Gauge Serial No. :85759
09/06/2023 3 24.8 92.6 P-1 96.5 22.3 96.0 95 D6938 Pass
Location : Retaining wall, STA 2+00.00, Elv/Depth :at finished grade
Comment : Gauge Serial No. :85759
09/06/2023 4 25.8 93.6 P-1 96.5 22.3 97.0 95 D6938 Pass
Location : Retaining wall, STA 0+20.00, Elv/Depth :13 feet below finished grade
Comment : Gauge Serial No. :85759
09/06/2023 5 19.7 91.0 P-1 96.5 22.3 94.3 95 D6938 Fail
Location : Sower trench, 75' to West of MH C5., Elv/Depth :7 feet below finished grade
Comment : re-compaction needed Gauge Serial No. :85759
09/06/2023 6 20.9 97.8 P-1 96.5 22.3 101.3 95 D6938 Pass
Location : Sower line, 108' to East of MH D1., Elv/Depth :6 feet below finished grade
Comment : Gauge Serial No. :85759
09/06/2023 7 16.9 90.1 P-1 96.5 22.3 93.4 95 D6938 Fail
Location : Storm line, 20 feet to awest of MH C5,, Elv/Depth :5 feet below finished grade
Comment : Re-compaction needed Gauge Serial No. :85759
09/06/2023 8 24.6 94.8 P-1 96.5 22.3 98.2 95 D6938 Pass
Location : Storm line, 117 feet to West of MH C5,, Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :85759
09/06/2023 8 24.6 97.1 P-1 96.5 22.3 100.6 95 D6938 Pass
Location : Storm line, 115 feet to East of MH D1, , Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :85759
09/06/2023 9 26.5 91.7 P-1 96.5 22.3 95.0 95 D6938 Fail
Location : Storm line, 81 feet to the West of MH C5,, Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, September 6, 2023
Reviewer Name / DateKenneth Mosman, September 18, 2023