Skip to content

Density Test Report

Date :10/13/2023
Project No :2022C235
Client Company :Jackson Demolition Service, Inc.
Arrival Time :10/13/2023 07:00
Onsite Hours :9:30
Name of the Project :Plant Gorgas Demolition and Grading
Project Location :460 Gorgas Rd, Parrish, AL 35580
Weather :Clear skies
Departure Time :10/13/2023 16:30
ASEC Technician Name :Avinash Bandham

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/13/2023 1 9.1 131.6 44789 131.9 9.5 99.8 98 D6938 Pass
Location : See attached drawing, Elv/Depth :Final grade
Comment : Gauge Serial No. :30942
10/13/2023 2 10.5 129.2 44789 131.9 9.5 98.0 98 D6938 Fail
Location : See attached drawing, Elv/Depth :Final grade
Comment : Gauge Serial No. :30942
10/13/2023 3 10.2 129.4 44789 131.9 9.5 98.1 98 D6938 Pass
Location : See attached drawing, Elv/Depth :Final grade
Comment : Gauge Serial No. :30942
10/13/2023 4 10.6 130.7 44789 131.9 9.5 99.1 98 D6938 Pass
Location : See attached drawing, Elv/Depth :Final grade
Comment : Gauge Serial No. :30942
10/13/2023 5 9.3 132.8 44789 131.9 9.5 100.7 98 D6938 Pass
Location : See attached drawing, Elv/Depth :Final grade
Comment : Gauge Serial No. :30942
10/13/2023 6 8.9 130.9 44789 131.9 9.5 99.2 98 D6938 Pass
Location : See attached drawing, Elv/Depth :Final grade
Comment : Gauge Serial No. :30942
10/13/2023 7 9.6 131.7 44789 131.9 9.5 99.8 98 D6938 Pass
Location : See attached drawing, Elv/Depth :Final grade
Comment : Gauge Serial No. :30942
Technician Signature / DateRamchandra Mogulla, October 13, 2023