- Home
- Density Test Report Report ID: 63054
- Edit Download Report
Density Test Report
Date :11/08/2023
Project No :2021C002
Client Company :CW Matthews
Arrival Time :11/08/2023 8:00
Onsite Hours :03:00
Name of the Project :Runway 9L End Around Taxiway
Project Location :HJAIA
Weather :sunny
Departure Time :11/08/2023 11:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
11/08/2023 | 1 | 6.9 | 115.8 | 16 | 124.0 | 8.7 | 93.4 | 90 | D6938 | Pass |
Location : | STA 7022+00, Elv/Depth :1 foot below finish grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
11/08/2023 | 2 | 11.7 | 114.5 | 16 | 124.0 | 8.7 | 92.3 | 90 | D6938 | Pass |
Location : | STA 7022+00, Elv/Depth :1.5 feet below finish grade | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, November 8, 2023