- Home
- Density Test Report Report ID: 63271
- Edit Download Report
Density Test Report
Date :12/06/2023
Project No :2023C195
Client Company :Toll Bros. Inc.
Arrival Time :12/06/2023 8:30
Onsite Hours :03:30
Name of the Project :Kimbal Bridge Tract
Project Location :Alpharetta
Weather :sunny
Departure Time :12/06/2023 12:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
12/06/2023 | 1 | 15.6 | 106.2 | 24209 | 111.6 | 16.5 | 95.2 | 90 | D6938 | Pass |
Location : | Sower line 25 feet to West of MH A10., Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
12/06/2023 | 2 | 16.7 | 103.5 | 24209 | 111.6 | 16.5 | 92.7 | 90 | D6938 | Pass |
Location : | Sewer line 45 feet to South of MH A11., Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
12/06/2023 | 3 | 17.2 | 106.4 | 24209 | 111.6 | 16.5 | 95.3 | 90 | D6938 | Pass |
Location : | at road in the front of Lot #15, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
12/06/2023 | 4 | 18.7 | 102.5 | 24209 | 111.6 | 16.5 | 91.8 | 90 | D6938 | Pass |
Location : | Road in the front of Lot #17, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
12/06/2023 | 5 | 16.9 | 104.2 | 24209 | 111.6 | 16.5 | 93.4 | 90 | D6938 | Pass |
Location : | Sewer line 19 feet to East of MH A10, Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, December 6, 2023
Reviewer Name / DateKenneth Mosman, March 08, 2024