Density Test Report

Date :12/08/2023
Project No :2023C141
Client Company :Toll Bros
Arrival Time :12/08/2023 8:00
Onsite Hours :05:00
Name of the Project :N. Gate - Old Atlanta Road
Project Location :Cumming
Weather :cloudy
Departure Time :12/08/2023 13:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
12/08/2023 1 21.2 96.9 24469 103.9 18.7 93.3 90 D6938 Pass
Location : Lot #30, Elv/Depth :2.5 below finished grade
Comment : Gauge Serial No. :85759
12/08/2023 2 17.8 98.7 24468 111.3 17.5 88.7 90 D6938 Fail
Location : Lot #29, Elv/Depth :2 feet below finished grade
Comment : Recompaction and retesting required Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, December 8, 2023
Reviewer Name / DateKenneth Mosman, March 08, 2024