- Home
- Density Test Report Report ID: 63294
- Edit Download Report
Density Test Report
Date :12/08/2023
Project No :2023C195
Client Company :Toll Bros. Inc.
Arrival Time :12/08/2023 13:00
Onsite Hours :03:00
Name of the Project :Kimbal Bridge Tract
Project Location :Alpharetta
Weather :cloudy
Departure Time :12/08/2023 16:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
12/08/2023 | 1 | 15.8 | 116.4 | 24209 | 111.6 | 16.5 | 90.1 | 90 | D6938 | Pass |
Location : | Water storm 42 feet east of MH 9G., Elv/Depth :6 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
12/08/2023 | 2 | 15.8 | 116.3 | 24209 | 111.6 | 16.5 | 90.0 | 90 | D6938 | Fail |
Location : | 17 feet to south of MH 9G., Elv/Depth :4 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
12/08/2023 | 3 | 18.2 | 105.3 | 24209 | 111.6 | 16.5 | 94.4 | 90 | D6938 | Pass |
Location : | Sewer line, 48 feet to west of MH C1., Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
12/08/2023 | 4 | 15.6 | 103.7 | 24209 | 111.6 | 16.5 | 92.9 | 90 | D6938 | Pass |
Location : | Sewer line 72 feet to east of MH C2., Elv/Depth :finished grade | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, December 8, 2023
Reviewer Name / DateKenneth Mosman, March 09, 2024