Density Test Report

Date :01/05/2024
Project No :2023C195
Client Company :Toll Bros. Inc.
Arrival Time :01/05/2024 11:00
Onsite Hours :05:00
Name of the Project :Kimbal Bridge Tract
Project Location :Alpharetta
Weather :sunny
Departure Time :01/05/2024 16:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
01/05/2024 1 16.3 123.5 24209 111.6 16.5 95.2 95 D6938 Pass
Location : Roadway (location shown in the picture), Elv/Depth :1 foot below finished grade
Comment : Gauge Serial No. :85759
01/05/2024 2 17.9 125.0 24209 111.6 16.5 95.0 95 D6938 Fail
Location : Water line, in the front of Lot #35, Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, January 5, 2024
Reviewer Name / DateKenneth Mosman, March 10, 2024