Density Test Report

Date :01/23/2024
Project No :2023C141
Client Company :Toll Bros
Arrival Time :01/23/2024 9:00
Onsite Hours :05:00
Name of the Project :N. Gate - Old Atlanta Road
Project Location :Cumming
Weather :sunny
Departure Time :01/23/2024 14:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
01/23/2024 1 18.9 101.3 24469 103.9 18.7 97.5 90 D6938 Pass
Location : Sewer line, 33 feet south of MH A11, Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :85759
01/23/2024 2 19.7 103.6 24469 103.9 18.7 99.7 90 D6938 Pass
Location : Storm sewer line, 35 feet north of MH A10., Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :85759
01/23/2024 3 17.9 103.9 24468 111.3 17.5 93.4 90 D6938 Pass
Location : Storm sewer line, 18 feet south of MH 2F , Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, January 23, 2024
Reviewer Name / DateKenneth Mosman, March 10, 2024