Density Test Report

Date :01/31/2024
Project No :2023C141
Client Company :Toll Bros
Arrival Time :01/31/2024 10:00
Onsite Hours :06:00
Name of the Project :N. Gate - Old Atlanta Road
Project Location :Cumming
Weather :sunny
Departure Time :01/31/2024 16:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
01/31/2024 1 15.7 103.4 24468 111.3 17.5 92.9 90 D6938 Pass
Location : Creek crossing (location shown in pictures), Elv/Depth :12 feet below finished grade
Comment : Gauge Serial No. :85759
01/31/2024 2 15.7 103.4 24468 111.3 17.5 92.9 90 D6938 Pass
Location : Creek crossing (location shown in pictures), Elv/Depth :13 feet below finished grade
Comment : Gauge Serial No. :85759
01/31/2024 2 17.1 105.7 24468 111.3 17.5 95.0 90 D6938 Pass
Location : Creek crossing (location shown in pictures) , Elv/Depth :12 feet below finished grade
Comment : Gauge Serial No. :85759
01/31/2024 3 16.6 103.6 24468 111.3 17.5 93.1 90 D6938 Pass
Location : Creek crossing(location shown in pictures), Elv/Depth :11 feet below finished grade
Comment : Gauge Serial No. :85759
01/31/2024 4 15.9 103.5 24468 111.3 17.5 93.0 90 D6938 Pass
Location : Creek crossing (location shown in pictures), Elv/Depth :11 feet below finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, January 31, 2024
Reviewer Name / DateKenneth Mosman, March 10, 2024