- Home
- Density Test Report Report ID: 63889
- This project is inactive from admin.Download Report
Density Test Report
Date :02/01/2024
Project No :2023C141
Client Company :Toll Bros
Arrival Time :02/01/2024 9:30
Onsite Hours :03:30
Name of the Project :N. Gate - Old Atlanta Road
Project Location :Cumming
Weather :sunny
Departure Time :02/01/2024 13:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
02/01/2024 | 1 | 18 | 101.7 | 24468 | 111.3 | 17.5 | 91.4 | 90 | D6938 | Pass |
Location : | Creek crossing (location shown in pictures), Elv/Depth :11 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
02/01/2024 | 2 | 15.5 | 103.6 | 24468 | 111.3 | 17.5 | 93.1 | 90 | D6938 | Pass |
Location : | Creek crossing (location shown in pictures), Elv/Depth :10 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
02/01/2024 | 3 | 15.8 | 104.7 | 24468 | 111.3 | 17.5 | 94.1 | 90 | D6938 | Pass |
Location : | Creek crossing (location shown pictures), Elv/Depth :12 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
02/01/2024 | 4 | 17.6 | 105.0 | 24468 | 111.3 | 17.5 | 94.3 | 90 | D6938 | Pass |
Location : | Sewer line 42 feet south of MH A10, Elv/Depth :5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
02/01/2024 | 5 | 20.6 | 101.0 | 24468 | 111.3 | 17.5 | 90.7 | 90 | D6938 | Pass |
Location : | Storm line 45 feet north of MH A9, Elv/Depth :4 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, February 1, 2024
Reviewer Name / DateKenneth Mosman, March 10, 2024