Density Test Report

Date :02/03/2024
Project No :2023C141
Client Company :Toll Bros
Arrival Time :02/03/2024 11:30
Onsite Hours :03:00
Name of the Project :N. Gate - Old Atlanta Road
Project Location :Cumming
Weather :sunny
Departure Time :02/03/2024 14:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/03/2024 1 14.3 100.6 24468 111.3 17.5 90.4 90 D6938 Pass
Location : Creek crossing (location shown in pictures), Elv/Depth :7 feet below finished grade
Comment : Gauge Serial No. :85759
02/03/2024 2 14.6 104.2 24468 111.3 17.5 93.6 90 D6938 Pass
Location : Creek crossing (location shown in pictures), Elv/Depth :7 feet below finished grade
Comment : Gauge Serial No. :85759
02/03/2024 3 17.3 101.2 24468 111.3 17.5 90.9 90 D6938 Pass
Location : Creek crossing (location shown in pictures), Elv/Depth :10 feet below finished grade
Comment : Gauge Serial No. :85759
02/03/2024 4 20.2 102.2 24468 111.3 17.5 91.8 90 D6938 Pass
Location : Water storm, 25 feet south of MH 1E, Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
02/03/2024 5 20.4 103.8 24468 111.3 17.5 93.3 90 D6938 Pass
Location : 45 feet north of MH 1H,, Elv/Depth :finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, February 3, 2024
Reviewer Name / DateKenneth Mosman, March 11, 2024