Density Test Report

Date :02/03/2024
Project No :2022C165
Client Company :Toll Bros. Inc.
Arrival Time :02/03/2024 14:30
Onsite Hours :02:00
Name of the Project :Northfield @ Polo Fields - Phase2
Project Location :Pittman Road, Cumming, GA
Weather :sunny
Departure Time :02/03/2024 16:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/03/2024 1 26.7 87.5 5 93.8 20.9 93.3 90 D6938 Pass
Location : Lot #18, Elv/Depth :2 feet below finished grade
Comment : Moisture contents more than 3 percent over optimum Gauge Serial No. :85759
02/03/2024 2 28.6 89.6 4 98.6 20.2 90.9 90 D6938 Pass
Location : Lot #19, Elv/Depth :2 feet below finished grade
Comment : Moisture contents more than 3 percent over optimum Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, February 3, 2024
Reviewer Name / DateKenneth Mosman, March 11, 2024